Camy Standard Battery Pack

所属分类: CAMY Standard Battery Pack

Non-stop, series-parallel online conversion, matching high and low voltage charging and discharging

028-64153944
Camy Standard Battery Pack
Camy Standard Battery Pack
Camy Standard Battery Pack
Camy Standard Battery Pack
+
  • Camy Standard Battery Pack
  • Camy Standard Battery Pack
  • Camy Standard Battery Pack
  • Camy Standard Battery Pack

产品详情

Development History and Planning of CAMY Battery Pack

Standardized Design

Single type of battery cell, module,  standard battery pack, high-voltage control unit (PDU) , with unified system architecture. Ensures low operation and maintenance cost, compatible with industrial  mining traction vehicles, engineering operation vehicles, engineering tractors, airport equipment, ships, forklifts, sightseeing vehicles, golf carts and other off-road mobile equipment or energy storage systems.

Modular Design

The combination of the array battery system and the distributed management system provides a variety of multi-level capacity  and voltage platform options. The modularization and standard package realize the system covering 48V~1000V high and low voltage systems, and online dynamic adjustment can also be realized through PDU control. The series-parallel mode meets the requirements of high-voltage charging in low-voltage operation or low-voltage charging in high-voltage operation.

Intelligent Design

Open battery management system based on operating data model of operating conditions, localized 5-year operating data storage, Ethernet interface, high-speed data transmission capability, flexible management of each cell, automatic identification of cell characteristics, and classification of multiple standard packages control.

Serialized Design

Power distribution control unit (BMS-PDU), matching different capacity and voltage platforms, can quickly meet the power distribution needs of different customer. When connecting standardized packs in series, and the maximum voltage can reach 1000V.

CAMY ABS-80V/304Ah/277Ah


1、Control each cell, quickly isolate and inhibit the spread of faults

2、Prevent heat diffusion, 100% utilization of battery cell life

3、Non-stop, series-parallel online conversion, matching high and low voltage charging and discharging

4、Take precautions and accurately judge electrical and battery fires

5、Long-lasting oxygen barrier, insulation, environmental protection and non-corrosive

6、Flexible grouping, oriented to battery swap mode and full life cycle cascade utilization

Array standard model

CMB1

CMB2

CMB3

CMB4

Structure

25S1P

25S1P

25S1P

25S1P*2

Standard battery pack volage rage

62.5~91.25V

62.5~91.25V

62.5~91.25V

62.5~91.25V

Power

22.16kWh

22.16kWh

22.16kWh

44.32kWh

Maximum continuous charging current

0.5C

0.5C

0.5C

0.5C

Standard Peak charging current (5s)

300A

300A

300A

300A

Maximum continuous discharge current

1C

1C

1C

1C

Peak discharge current(30s)

400A

400A

400A

600A

Discharging temerpature range

-30~60℃

-30~60℃

-30~60℃

-30~60℃

Charging temerpature range

0~55℃

0~55℃

0~55℃

0~55℃

cycle life(times)

3000

3000

3000

3000

insulation

≥20MΩ

≥20MΩ

≥20MΩ

≥20MΩ

Heating system

500W,@80Vdc

500W,@80Vdc

500W,@80Vdc

500W*2,@80Vdc

IP level

IP67

IP67

IP67

IP67

weight(KG)

177±3

177±3

182±3

353±3

Size(mm)

980*570*250

1080*510*250

970*550*270

1215*830*275

Specific energy

>126Wh/Kg

>126Wh/Kg

>126Wh/Kg

>126Wh/Kg

conbination range

62.5~1095V

62.5~1095V

62.5~1095V

62.5~1095V

power range

22.16~265.92kWh

22.16~265.92kWh

22.16~265.92kWh

44..32~531.84kWh

strength level

1500V

1500V

 

1500V

Appearance

 

 

 

 

 

 

 

关键词:Camy Standard Battery Pack